In most cases, battery systems are exposed to variety of environmental influences. This includes not only mechanical stress, but also, among others, climatic or thermal environmental conditions.
We will be able to use the following climatic and temperature systems for testing your batteries.
3 climatic test cabinets and 3 temperature test cabinets with 0.35 m³ test space
Test space (W x D x H): 650 mm x 720 mm x 750 mm
Change rate cooling and heating: 10 K/min
Temperature range: -48 °C to +180 °C
Humidity range: 10 % to 98 % RH
Example image, source: CTS GmbH / WKM GmbH & Co. KG
2 climatic test cabinets with 1 m³ test space
Test space (W x D x H): 1000 mm x 1100 mm x 900 mm
Change rate cooling and heating: 10 K/min
Temperature range: -48 °C to +180 °C
Humidity range: 10 % to 98 % RH
Example image, source: CTS GmbH / WKM GmbH & Co. KG
2 walk-in temperature test chambers and 1 walk-in climatic test chamber with 11,5 m³ test space
Test space (W x D x H): 2400 mm x 2400 mm x 2000 mm
Change rate cooling and heating: 5 K/min
Temperature range: -45 °C to +150 °C
Humidity range: 10 % to 95 % RH
Example image, source: CTS GmbH / WKM GmbH & Co. KG
1 vibration temperature test chamber with 11 m³ test space
Test space (W x D x H): 2500 mm x 3115 mm x 1500 mm
Change rate cooling and heating: 5 K/min
Temperature range: -45 °C to +150 °C RH
Our vibration climatic test chamber, source: CTS GmbH / WKM GmbH & Co. KG